#Vector License Manager

#Introduction

Open iT supports Vector usage reporting. If you have dongle license data, you only need to activate the Vector dongle data collection and this will produce the following aggregated data types used for historical reporting:

On the other hand, the following sections will guide you on the required configuration for license manager utility polling where Open iT supports Vector usage reporting by polling the license servers at regular intervals to get the current status of its license use and availability.

An Open iT client is installed on your license server for this collection. The data collector/preprocessor gathers the current license usage information from the license manager every hour using a 5-minute sample interval, triggering the data collection process. It also processes the gathered license usage. Once the data is preprocessed, it is transmitted to the Core Server, according to the client's timezone, for further storage, completing the license usage data collection and processing.

License Manager Utility Polling Workflow

License Manager Utility Polling Workflow

This will produce the following aggregated data types used for historical reporting:

#Requirements

#Configuring Data Collection

These are the required steps to activate and configure collection of Vector usage data.

  1. Go to the Components directory, which is by default in C:\Program Files\OpeniT\Core\Configuration\Components, and back up the licpoll.xml configuration file.

  2. Open a command prompt with Administrator level privileges.

  3. Go to the bin directory, which is by default in C:\Program Files\OpeniT\Core\bin, run the command:

    Command Syntax
    cd $BIN_DIR
    Example
    cd C:\Program Files\OpeniT\Core\bin
  4. Once in the directory, activate the collection of Vector data, run the command:

    Command Syntax
    openit_confinit -c "licpoll.license-types.vector-sample.active=true"
  5. Update the configuration file, run the command:

    Command Syntax
    openit_confbuilder --client

    Make sure no errors are encountered.

Advanced Configuration

Refer to the Vector Data Collection Configuration table to learn more about Vector configuration in licpoll.xml.

Object NameAccepted ValueDescription
activeBoolean (true or false)Setting this to true activates Vector usage data collection.
typeString (e.g., Vector)The license manager type.
intervalTimespan (e.g., P30S, P5M, P1H)The span of time between each polling round (it is recommended to set a value no less than P1M).
offsetTimespan (e.g., P30S, P5M, P1H)The span of time the aligned poll time decided by interval is shifted.
product-nameString (e.g., server;daemon)This object is defined if a vendor license name other than the default Vector=%server%;vector will be used.
status-commandFileName (i.e., ${OpeniT.directories.bin}/openit_vectorstat)The binary used to obtain status from the license manager.
status-command.argumentsString (e.g., -hostid)The arguments used for the status command.
Vector Data Collection Configuration

#Verifying Data Collection

After configuration, you can verify that the data is collected by following these steps:

  1. Open a command prompt with Administrator level privileges.

  2. Go to the bin directory, which is by default in C:\Program Files\OpeniT\Core\bin, run the command:

    Command Syntax
    cd $BIN_DIR
    Example
    cd C:\Program Files\OpeniT\Core\bin
  3. Run the command:

    Command Syntax
    openit_licpoll -# 1
  4. Verify that the temp directory, which is by default in C:\ProgramData\OpeniT\Data\temp, contains a LicPoll directory containing .data and status-*.log files.

#Next Steps?

   Renaming Vendor License   Renaming Features   Create and Add Report    License Monitor

    We value your feedback!

    Please take a few minutes to complete our survey and share your thoughts on your recent experience with our documentation.

    Take survey