Skip to main content
Version: 10.2

Altium Concord Pro

Introduction

Open iT supports Altium Concord Pro usage reporting by polling the license servers at regular intervals to get the current status of its license use and availability.

For this collection, the data source is through an API. The data collector/preprocessor initiates the license status utility every hour using a 5-minute sample interval, triggering the data collection process. The license status utility requests the current license usage data from the license manager portal. After the license manager portal provides the requested data, the license status utility passes this information to the data collector/preprocessor. The data collector/preprocessor processes the data, preparing it for transmission. Finally, the preprocessed data is sent to the Core Server every night, according to the client's timezone, for further storage, completing the license usage data collection and processing.


License Manager Utility Polling Workflow through API

License Manager Utility Polling Workflow through API


This will produce the following aggregated data types used for historical reporting:

The following sections will guide in setting up the necessary configuration to collect and send the required data to the server.

warning

Apply the configurations shown in the Open iT Core Client.

Requirements

Configuring Data Collection

These are the required steps to activate and configure collection of Altium Concord usage data.

  1. Go to the Components directory, which is by default in C:\Program Files\OpeniT\Core\Configuration\Components, and back up the licpoll.xml configuration file.

  2. Open a command prompt with Administrator level privileges.

  3. Go to the bin directory, which is by default in C:\Program Files\OpeniT\Core\bin, run the command:

    Command Syntax
    cd $BIN_DIR
    Example
    cd C:\Program Files\OpeniT\Core\bin
  4. Once in the directory, copy the object node genericlicense-sample and rename it to your desired name. In this example, we will use altiumconcordpro. Run the command:

    Command Syntax
    openit_confinit -c "licpoll.license-types.genericlicense-sample=>licpoll.license-types.altiumconcordpro"
    warning

    Element names cannot contain parentheses ( or ) because they are not valid XML element names.

  5. Activate the collection of Altium Concord Pro data, run the command:

    Command Syntax
    openit_confinit -c "licpoll.license-types.altiumconcordpro.active=true"
  6. Set the arguments to the status command, run the command:

    Command Syntax
    openit_confinit -c "licpoll.license-types.altiumconcordpro.status-command.arguments=AltiumConcord <api_url>"

    where <api_url> is the corresponding valid URL with the port number of the Altium Concord API.

    Example
    openit_confinit -c "licpoll.license-types.altiumconcordpro.status-command.arguments=AltiumConcord http://localhost:1804"
  7. Update the configuration file, run the command:

    Command Syntax
    openit_confbuilder --client

    Make sure no errors are encountered.

Advanced Configuration

Refer to the Altium Concord Data Collection Configuration table to learn more about Altium Concord configuration in licpoll.xml.

Object NameAccepted ValueDescription
activeBoolean (true or false)Setting this to true activates Altium Concord usage data collection.
typeString (e.g., GenericLicense)The license manager type.
intervalTimespan (e.g., P30S, P5M, P1H)The span of time between each polling round (it is recommended to set a value no less than P1M).
offsetTimespan (e.g., P30S, P5M, P1H)The span of time the aligned poll time decided by interval is shifted.
product-nameString (e.g., server;daemon)This object is defined if a vendor license name other than the default GenericLicense=%hosttype% will be used.
license-serverString (e.g., desktop123win)The license server name.
status-commandFileName (i.e., ${OpeniT.directories.bin}/genlicutil)The binary used to obtain status from the license manager.
status-command.argumentsString (e.g., AltiumConcord http://localhost:1804)The arguments used for the same status command. Use the format AltiumConcord <api_url>.
Altium Concord Data Collection Configuration

Verifying Data Collection

After configuration, you can verify that the data is collected by following these steps:

  1. Open a command prompt with Administrator level privileges.

  2. Go to the bin directory, which is by default in C:\Program Files\OpeniT\Core\bin, run the command:

    cd $BIN_DIR
    Example
    cd C:\Program Files\OpeniT\Core\bin
  3. Run the command:

    Command Syntax
    openit_licpoll -# 1
  4. Verify that the temp directory, which is by default in C:\ProgramData\Data\temp, contains a LicPoll directory containing .data and status-*log files.

Next Steps?